Ultra High Pressure Liquid Chromatography (UHPLC)

1.7um Fortis C18 UHPLC Columns

Specially designed optimised small particle for use in ultra high pressure chromatography (UHPLC), optimise the operation of your Jasco X-LC(TM), Agilent 1290(R) or Acquity UPLC(R) system

1.7um UHPLC columns can be used in gaining resolution and sensitivity under the correct operating conditions, small particles will not lose efficiency even at higher linear velocity.  Whilst sensitivity will increase with the increased efficiency afforded by Fortis 1.7um particles in UHPLC. 

1.7um Fortis C18 UHPLC particles are fully scalable with Fortis C18 analytical 3um, 5um and 10um particles. The same exact surface area, 380m2/g is used for each Fortis particle size.  Transfer of methods is therefore guarenteed from UHPLC to HPLC.  This relatively high surface area means that the analyst can choose between higher peak capacity or a similar retention profile to currently available 1.7um particles.  If a similar retention profile is required then it is possible to use shorter Fortis C18 column which can also lead to lower backpressure for a given linear velocity.   

Available in several phase chemistries; C18, Diphenyl, HILIC, C8 and Cyano, 1.7um Fortis UHPLC columns can provide selectivity as well as high efficiency. Please request further information to find out the full selectivity available, and what separations can be achieved.  Check out our Fortis Diphenyl page to see the isomer/metabolite applications that can be achieved with Fortis Diphenyl and its unique diphenyl character. Click here

 

Request further literature on this new product:

C18 C8  
F18-020501 1.7um Fortis C18 100 x 2.1mm  F08-020501 1.7um Fortis C8 100 x 2.1mm   
F18-020301 1.7um Fortis C18 50 x 2.1mm F08-020301 1.7um Fortis C8 50 x 2.1mm  
F18-020201 1.7um Fortis C18 30 x 2.1mm  F08-020201  1.7um Fortis C8 30 x 2.1mm   
DiphenylHILIC  
FPH-020501 1.7um Fortis Diphenyl 100 x 2.1mm FHI-020501 1.7um Fortis HILIC 100 x 2.1mm  
FPH-020301 1.7um Fortis Diphenyl 50 x 2.1mm FHI-020301 1.7um Fortis HILIC 50 x 2.1mm 
FPH-020201 1.7um Fortis Diphenyl 30 x 2.1mm  FHI-020201   

1.7um Fortis HILIC 50 x 2.1mm

CyanoHILIC DIOL  
FCN-0205011.7um Fortis Cyano 100 x 2.1mm FDI-020501  1.7um Fortis HILIC DIOL 100 x 2.1mm   
 FCN-0203011.7um Fortis Cyano 50 x 2.1mm  FDI-020301  1.7um Fortis HILIC DIOL 50 x 2.1mm  
 FCN-020201  1.7um Fortis Cyano 30 x 2.1mmFDI-020201

1.7um Fortis HILIC DIOL 30 x 2.1mm

  
 AMINOH2o  
FNH-020501 1.7um Fortis Amino 100 x 2.1mm FHO-020501  1.7um Fortis H2o100 x 2.1mm  
FNH-020301   1.7um Fortis Amino 50 x 2.1mm FHO-020301    1.7um Fortis H2o 50 x 2.1mm  
FNH-020201  1.7um Fortis Amino 30 x 2.1mm  FHO-020201   1.7um Fortis H2o 30 x 2.1mm   

If you are looking for High throughput screening (HTS) in normal 400bar LC systems then we would recommend a 2.5um particle with high flow rates in order to achieve the best peak capacities.  Fortis Pace columns packed with the stationary phase of your choice will improve your speed of analysis. Find out more about Fortis Pace >>